欧兰公司双线路主站 燃烧流体测量设备分站

北京欧兰科技发展有限公司




Specifications 1)

Model PG403 PG403-SH PG503 PG703 PG703-DFG
OPG specifications
Output wavelength tuning range
SH - 210-410 nm - - -
Signal 410-709 nm 700-1000 nm 1400-1850 nm 1550-2020nm
Idler 710-2300 nm 1150-2200 nm 2500-4450 nm 2250-3350 nm
DFG - - - - 3350-16000 nm
Output pulse energy 2)
SH 3) - 10 µJ - - -
Signal 50 µJ 70 µJ 60 µJ
Idler 4) 15 µJ 25 µJ 20 µJ
DFG 5) - - - - 6 µJ
Pulse repetition rate 1000 Hz
Linewidth < 12 cm-1 < 12 cm-1 < 6 cm-1
Typical pulse duration 6) 15 ps 20 ps 20 ps
Scanning step, nm
SH - 0.05 nm - - -
Signal 0.1 nm
Idler 1 nm
DFG - - - - 1 nm
Typical beam size 7) ~ 3 mm
Beam divergence 8) < 2 mrad
Beam polarization 9)
SH - vertical - - -
Signal horizontal
Idler vertical vertical horizontal vertical
DFG - - - - vertical
Pump laser requirements
Min pump energy10)
at 1064 nm - - 0.9 mJ
at 532 nm - 0.45 mJ -
at 355 nm 0.3 mJ - -
Pulse duration 11) 10-30 ps
Beam polarization at pump wavelength vertical horizontal horizontal
Beam size 11) 2-3 mm
Beam divergence < 1 mrad
Beam profile homogeneous, without hot spots, Gaussian fit > 90 %
Recommended pump source PL2210A-TH PL2210A-TH PL2210A-SH PL2210A PL2210A
Physical characteristics
Size (WxHxL) 456x273x605 mm 456x273x1026 mm 456x273x605 mm 456x273x605 mm 456x273x1026 mm
Operating requirements
Room temperature 15-30 °C
Mains voltage 100-240 V single phase, 47-63 Hz
Power consumption < 120 W

1) All specifications are subject to change without notice. Parameters marked typical are not specifications. They are indications of typical performance and will vary with each unit we manufacture. Unless stated otherwise, all specifications are measured at 450 nm for PG403 units, 800 nm for PG503 units, and 1620 nm for PG703 units.

2) Pulse energies are specified at selected wavelengths. See typical tuning curves for pulse energies at other wavelengths.

3) Measured at 250 nm.

4) Measured at 1000 nm for PG40x units, 1620 nm for PG503 and 3000 nm for PG703 units.

5) Measured at 5000 nm.

6) Estimated assuming 30 ps at 1064 nm pump pulse. Pulse duration varies depending on wavelength and pump energy.

7) Beam diameter at the FWHM point. Can vary depending on the pump pulse energy.

8) Full angle measured at the 1/e2 point.

9) Separate output ports for SH, signal, idler and DFG ranges.

10) Max pump energy is limited by available non-linear crystal sizes.

11) Should be specified while ordering if non-EKSPLA pump laser is used.

基于博卡先锋SiteEngine构建
北京欧兰科技发展有限公司 版权所有 电子邮件:info@oplanchina.com,oplan@263.net
联系电话:010-62623871, 62616041,62612809 传真:010-59713638
地址:北京市海淀区上地十街1号辉煌国际中心1号楼1006室 邮政编码:100085 京ICP备07038319号-2
Processed in 0.080 second(s), 3 queries